8
Warner Electric • 800-825-9050 819-0452
Torque (kgfcm) = 1.152 X Torque (lb.in.)
Torque vs. Current Curve (Typical)
Type: PMC-10A
(kgfcm) (lb. in.)
18
10
4
0
0.1
0.2
0.3
0.8
5.2
6.9
8.6
10.4
12.2
15.6
Rated Current 0.56 Amp
Rated Torque 10 Kgfcm (8.6 lb. in.)
Torque
Current (Amp.)
3.5
1.7
14
0.4
0.5
2
6
12
16
8
0.6 0.7
13.9
3
Torque vs. Current Curve (Typical)
Type: PMC-20A
(kgfcm) (lb. in.)
30
20
15
0
.01
0.6
4.3
8.7
13.0
Rated Current 0.625 Amp
Rated Torque 20 Kgfcm (17 lb. in.)
Torque
Current (Amp.)
25
0.2
10
5
0.3
17.4
21.4
26.0
0.4
0.5
0.7
3
Torque vs. Current Curve (Typical)
Type: PMC-40A
(kgfcm) (lb. in.)
50
30
20
0
0.1
0.6
4.3
8.7
13.0
Rated Current 0.75 Amp
Rated Torque 40 Kgfcm (34 lb. in.)
Torque
Current (Amp.)
40
0.2
10
0.3
17.4
21.7
26.0
0.4
0.5
0.7
0.9
0.8
30.4
34.7
39.1
43.4
3
Komentarze do niniejszej Instrukcji